Request a budgetory quotation for HPTLC Products

In the Indian bureaucratic context, it is important for the Govt. scientist to describe accurately the product specs, in order to buy the appropriate make of analytical equipment, which will be an asset and produce the desired results, over a long period of time.

Since products are consistently changing, it is advisable to contact us for the appropriate configuration and latest specs much before tendering.

CAMAG HPTLC

 
CAMAG PRODUCT SPECIFICATIONS
 
System Manager Controlled High Performance Thin Layer Chromatograph for quantification, identification, finger printing and micro-preparative separations
 
Integrated HPTLC SYSTEM MANAGER
software
SAMPLE SPOT APPLICATOR –
(Camag Nanomat)
   
Semi-auto / Sample Applicator :
(Camag Linomat 5)
AUTOMATIC TLC SAMPLER –
(Camag ATS 4)
   
CHROMATOGRAM DEVELOPMENT CHAMBERS (Twin Trough Chambers) HORIZONTAL VARIO CHAMBER FOR METHOD DEVELOPMENT – (Vario Chamber)
   
AUTOMATIC DEVELOPING CHAMBER WITH HUMIDITY CONTROL –(Camag ADC -2) GRADIENT AUTOMATIC MULTIPLE DEVELOPMENT CHAMBER – (Camag AMD-2)
   
CHROMATOGRAPHY VISUALISATION –
(UV Cabinet)
IMMERSION DEVICE FOR DERIVATISATION
   
TLC / HPTLC PLATE HEATER AUTOMATIC TLC SPRAYER
   
PHOTO RECORDING - capable UV Cabinet Camag Smart Digi. TLC SCANNER 4
   
PHOTODOCUMENTATION Under GLP – (Camag Visualiser) CUTTING DEVICE FOR TLC/HPTLC GLASS PLATES:
   
AUTOMATIC TLC PLATE COATER
BIO - LUMINIZER
   

OPTIONS FOR TLC/HPTLC SCANNER
Multi wavelength scans upto 31 wavelengths. Data stored. Auto calculation. Data displayed in 3 ways. Colour plots of data and quantification with respect to λ max of separated fractions. Also in absorption & luorescence mode.

Spectrum Library. Facility to create your own UV-VIS library. 999 spectra storage per file. All files searched automatically and sequentially for λ max as well as Rf.

Collaction of Spectra : A library of 750 pre-recorded spectra from HPTLC plates. For narcotic, toxicological & forensic use.

Qualification - Software to thoroughly check and aid in remote diagnosis of opticals, mechanicals and electronics of the scanner. Auto correction of lamp positioning and monchromator. IQ – OQ.

Track optimization – Eliminates any errors of plate positioning or slightly irregular movement of fractions. Non –GLP.

Dual wavelength – Enables subtraction of data measured at two wavelengths.

SOLVENT FRONT MONITORING DEVICE
To notify acoustically & visually that the mobile phase has reached the desired developing distance during chromatogram development. Works with glass plates being developed in developing glass tanks of sizes 20 x 20 cm, 20 x 10 cm, 10 x 10 cm.

G] SPARES, ACCESSORIES, CONSUMABLES, PREINSTALLATION REQUIREMENTS
Supplier must offer free installation, frequent training, standard substances where possible, local lab support, local spares stock etc. HPTLC System must meet all latest requirements of safety, conformity, ISO, GLP etc.

H] Other requirements :
Validation of instruments should be routinely possible. System should be upgradable. Since analytical research will be required to standardize new methods, we expect support for the suppliers in the form of literature survey, method development, method standardization, double check of analysis etc without any charge, locally from India.

Request a budgetory quotation for HPTLC Products


In the Indian bureaucratic context, it is important for the Govt. scientist to describe accurately the product specs, in order to buy the appropriate make of analytical equipment, which will be an asset and produce the desired results, over a long period of time.

Since products are consistently changing, it is advisable to contact us for the appropriate configuration and latest specs much before tendering.

IATROSCAN

Click here to view Image

IATROSCAN SPECIFICATIONS

 

 

TLC-FID Chromatograph with Flame Ionisation Detector
Able to scan sequentially and automatically, upto 10 Chromarods. Scan speed selectable from 25 to 60 sec. / chromarod in 5 sec. increments. 4 scanning modes blank, normal, origin and partial pyrolysis. Auto-zero adjustment. Upgradable with flame Photometric Detector. With sutable chromatography s/w and accessories.

Flame Photometric Detector
Sulphur and phosphorus specific detector. Emission line detected. Works in tandem with FID. Detects either S or P, at a time. Able to scan sequentially and automatically, upto 10 Chromarods. Scan speed selectable from 25 to 60 sec. / chromarod in 5 sec. increments. 4 scanning modes blank, normal, origin and partial pyrolysis. Auto-zero adjustment. Upgradable with flame Photometric Detector. With sutable chromatography s/w and accessories.

Separating Medium
“CHROMAROD” ™ Quartz rods, circular, 5 um long and 1 mm diameter.
Sintered with a layer of adsorbent (silica gel). Rods are reusable 50 to 200 times.

Software for Iatroscan
Dual channel chromatography software along with hardware for use with Iatroscan. Specially suitable for Iatroscan. All modern chromatographic parameters available. External & internal standard. Built-in I/O test. Comparison of two chromatograms.

With accessories, starter – kit, consumables.

A) CONSUMABLES
Chromarod – S III( 10 pcs / box )

B) CHROMATOGRAPHY ACCESSORIES
TLC Development Tank, DT – 150 Made of clear, transparent solvent front to be seen correctly, pk of 6.

Chromarod Storage Chamber DE-3, pk of 6.
Rod dryer TK-8. Digital temp. control for uniform drying of Chromarods.
Chromarod holder SD-6, pk of 6.
Micro-dispenser 1 to 5 L
Replacement tubes for dispenser (pk of 100), pk of 1000

Request a quotation for Iatroscan TLC/FID Chromatography


SES Spotters For Iatroscan

 

Click here to view Details

Specification

 
 
 
     
     
   
     
     
     
  Best viewed in IE 5+ and in 1024 x 768 resolution Copyright © 2008, ANCHROM. All Rights Reserved